Field verification program — Phase 0–1 (Claxton and Demory)
Purpose: Tie Phase 0–1 execution to repeatable site work at SITE_HOME (Claxton, Anderson) and SITE_FARM (Demory, Campbell)—methods and evidence contracts only. Do not pre-fill results; each visit updates baselines, worksheets, and missing data register rows via parcel evidence intake workflow.
Legend — Site: C = Claxton / SITE_HOME · D = Demory / SITE_FARM · Both = both.
Legend — Desktop vs field: Desktop = GIS, portals, calls, quotes without standing on dirt · Field = boots on ground · Both = desk prep + mandatory field confirmation.
Templates: Field observation template package — two-site.
Gates / tasks: V1–V12, G1–G3 on Validation backlog and decision gates; G1–G8 “major spend” alignment on Validation — before major spend.
Sensor / RF doctrine: Farm sensor architecture — Demory farm site · Sensor checklist matrix — Demory farm.
90-day bundling: First 90 days — operator packet (East Tennessee two-site) maps weeks 1–12 to this program’s sections for pilot execution.
1. Site walks and boundaries
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Orienting walk (buildings, fields, hazards, stock routes) |
Both |
Every other row assumes you know where things are |
Walk with printed map / tablet; use visit header template |
Dated log, photo roll IDs, fact class per fact |
All V tasks; R14 context |
Field |
| Fence + boundary walk (segments, gates, corners) |
D primary; C if livestock boundary |
V3; legal/settlement risk if fence ≠ line |
Template §B; flag Unknown corners |
Segment table → Infrastructure baseline |
V3; G1 fence CAPEX; deed/title (V8 surface) |
Field |
| Stake / corner ambiguity list |
Both |
Blocks confident fence/water CAD |
GPS optional; do not claim survey accuracy |
List of IDs needing surveyor |
G1; missing register §1 |
Field |
| Handling / load-out / corral as-built |
D |
V6 timing; welfare |
Sketch + photos + dimensions where safe |
Row in site inventory |
V6; Phase 2 ops |
Field |
2. Access and road checks
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Primary ingress route (pavement → driveway → lane) |
Both |
Trip batching + emergency response |
Template §C; wet/dry passes |
Segment photos, mud/ice notes |
Trip policy; R14 |
Field |
| Haul / equipment path (turn radii, soft spots) |
D |
Hay, stock trailer, drill timing |
Drive + walk with load surrogate if legal/safe |
Pin map + season note |
G1 earthwork; capital plan |
Field |
| Easement / shared lane facts |
Both |
R13; who maintains |
Desk: title index → Field: match posts/signs |
Redacted letter or map in raw/ + source-note |
V8 (legal); R13 |
Both |
| 911 / official address sanity |
Both |
Permits, utilities, WAN billing |
Desk: county GIS/911; Field: mailbox/sign match |
Capture path + photo |
Workflow “Official farm address” row |
Both |
3. Drainage and erosion observations
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Crown / ditch / culvert / rolling dip inventory |
D; C driveway |
R14; winter access |
Walk in rain or soon after; measure only if trained |
Labeled photo series + segment IDs |
V2 routing; R14 |
Field |
| Active rills / gullies / sediment at gates |
D |
Sediment traps gates; V3 |
Flag + GPS optional |
Before/after photos when fixed |
R14; G1 civil line |
Field |
| Ponding / seasonally wet panels |
D |
V1 wet limitation; fence post rot |
Walk with WSS map on tablet |
Polygon sketch on worksheet |
V1; V4 |
Both |
| Stream / buffer observation (no work in buffer) |
D |
TDEC / liability |
Visual only from legal access |
Photo + “no disturbance” note |
V2; R10 |
Field |
4. Utility and service verification
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Electric account structure (meter IDs, rate class) |
Both |
Loads + broker UPS story |
Call/portal; redact in wiki |
Provider + unknowns only on Utility baseline |
Capital; smart-tech |
Desktop |
| Will-serve / transformer / single vs three-phase |
Both |
Pumps, cold, shop |
Utility engineer visit or letter |
PDF in raw/ + source-note |
V2 pump ceiling; G1 |
Both |
| Domestic vs ag water meters |
Both |
Books + drought planning |
Field locate meters; photo labels |
Table update |
Revenue / COA alignment |
Field |
| Well / pump / pressure tank walkdown |
D (primary) |
V2 |
Visual + safe sound check; hire for drawdown test |
Log + contractor report if done |
V2, V4 |
Field |
| Septic / OSSS locate + setback sketch |
C; D if structures |
V8 buildability |
County env. health + field locate lids |
Sketch + permit # if issued |
V8; homestead CAPEX |
Both |
| ISP / LTE / Starlink obstruction sketch |
C office; D pilot pins |
V10 |
Desk: coverage maps → Field: obstruction photos |
Pin list + signal meter screenshots |
V10; G8 |
Both |
| 811 process readiness (before any dig) |
Both |
Legal + safety |
Read TN811 captures; file ticket when digging |
Ticket # in private runbook |
All trenching |
Desktop |
5. Power and load observation
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Main panel photo + breaker map (de-identified) |
Both |
Loads register truth |
Safe photo; turn off before opening if not qualified |
Annotated diagram in raw/ |
Loads register |
Field (hire electrician if needed) |
| Duty-cycled loads spot-check (well, heat tape, cooler) |
Both |
Off-grid / CS-5 story at D |
Clamp meter window if competent; else log run hours |
Time-series CSV or notebook |
G8; Demory power doctrine |
Field |
| Generator / transfer switch test |
Either |
Degraded mode |
Exercise per manual; log |
Test log |
MV-8 drills |
Field |
| Homelab / edge rack measured draw |
C |
Pcrit / Popt coupling |
PDU or UPS readout |
kWh sample |
Power domains — Demory cross-site budget |
Field |
6. Sensor pilot placement
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Candidate mount points (height, sun, theft, stock rub) |
D |
One-pilot discipline |
Tag photos + pole/tree ID |
Matrix row → Sensor checklist matrix |
Stop rules telemetry scope |
Field |
| Gateway / concentrator elevation + backhaul |
D |
RF vs WAN separation |
Map LOS to home vs LTE; no trench without 811 |
Sketch + pin |
Farm sensor architecture |
Both |
| Soil probe / tank level pilot “pencil install” |
D |
Prove SoR path |
Single device; document asset ID |
farmOS/log stub or spreadsheet |
Telemetry system of record — boundaries and authority |
Field |
| Spurious RF noise scan (microwave, motors) |
D |
Avoid false automation |
Short spectrum notes or “motor on/off” test |
Log |
Automation stop rules — two-site smart farm |
Field |
7. Controller and gateway location validation
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Barn / shed environment (dust, temp, Ethernet pull) |
D |
k3s / Pi survival |
Thermometer + dust visual; cable path |
Photo + max/min temp guess |
Platform doctrine |
Field |
| Enclosure + grounding + surge path |
D |
Lightning / Pcrit |
Visual inspection; electrician for bonding |
Photo + defer note if not qualified |
DR / safety |
Field |
| Homelab as control plane reachability |
C |
When WAN down |
VPN/overlay test from D phone hotspot |
Latency log |
Remote access model |
Both |
| UPS / battery maintenance access |
C |
Graceful shutdown |
Physical clearance check |
Photo |
MV drills |
Field |
8. Buildability, septic, and permit follow-ups
| Verification item |
Site |
Why it matters |
Method |
Evidence to record |
Gates / decisions affected |
Desktop vs field |
| Zoning district + permitted ag structures letter |
Both |
V8 |
Planning desk request |
PDF in raw/ + source-note |
V8; G1 |
Desktop |
| Setback field verify (tape from foundation corners) |
Both |
Maps lie |
Measure only where safe/legal |
Sketch |
V8 |
Field |
| Flood zone field check (signs of ponding vs map) |
Both |
Insurance + build |
FEMA layer on tablet + walk |
Photo + zone print |
V9; build siting |
Both |
| Perc / morph if required |
C |
ADU / shop expansion |
County-scheduled test |
Report in raw/ |
Capital sequencing |
Field |
Program cadence (suggested)
| Cadence |
Bundle |
| Every Demory trip |
Access (§2) + one infrastructure slice (§1 or §3) + one utility/power spot (§4–5) |
| Quarterly |
Full fence segment progress (§1), drainage after heavy rain (§3), insurance/agent delta (V9) |
| Before any dig |
§4 811 + §8 permits |